EAN900
Users Manual
Copyright © EverFocus Electronics Corp,
Release: Dec. 2009 Rev.D
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - User’s Manual

EAN900 User’s Manual Copyright © EverFocus Electronics Corp, Release: Dec. 2009 Rev.D

Strany 2

EAN900 104. SETTING Click this button to display the setup menu.

Strany 3

EAN900 114.1 System Info System information and system log check of the setup menu can be performed on this page. The “System Info” page has 2 tab

Strany 4

EAN900 124.1.2 Log System Log: Date/Time: displaying date and time of the log. Log message: all information and event message, including logi

Strany 5 - TABLE OF CONTENTS

EAN900 134.2 User Config Live view configuration is to be set by user. Each login user can make his/her own settings for the following items: T

Strany 6 - 3. ACCESSING THE CAMERA MENU

EAN900 14 Time Format: 24 Hours or 12 Hours. Press Apply to apply the setting changes or Reset to reset without saving the change. Recording/Sn

Strany 7

EAN900 15change. 4.3 Network The network settings and the settings relating to Network, DDNS, Bandwidth, SMTP/FTP and Network Alarm can be configu

Strany 8

EAN900 16DHCP: Configure the DHCP server not to assign the same IP addresses used for the other network cameras and PCs whose IP address is unique

Strany 9

EAN900 17Press Apply to apply the setting changes or Reset to reset without saving the change. Port Setting HTTP Port Port number for HTTP/WEB

Strany 10 - 4. SETTING

EAN900 18○ www.sitelutions.com ○ www.dyndns.com ○ www.no-ip.com Enable: Check the box to enable DDNS setting. Service ISP: If you choose Ever

Strany 11 - EAN900

EAN900 19network. This is a useful function when connecting the camera to busy or heavily loaded networks. The default setting is Unlimited. Max.

Strany 12

EAN900 2Product Name: EAN900 EverFocus IP Network Cameras Model Number(s): EAN900 FCC Notice "Declaration of Conformity Information" Th

Strany 13 - 4.2 User Config

EAN900 20Authentication: Check the box, if the SMTP server requires Authentication (user/ password). User name: Input the login user ID if the SM

Strany 14

EAN900 214.3.5 Network Alarm (reserved for PowerCon) Set Network Alarm This function is reserved for PowerCon software, for the detail setting p

Strany 15 - 4.3 Network

EAN900 224.4.1 Multi Streaming Stream Setting The system can output 3 video streams simultaneously. For each of them, user can set compression

Strany 16

EAN900 23Frame Rate: max. 15 fps @ 1280 x 1024 ; max. 15 fps @ 1280 x 960 ; max. 20 fps @ 1280 x 720 ; max. 30 fps @ 640 x 480. Press Apply to ap

Strany 17

EAN900 24Camera setting Brightness: to increase or decrease contrast value of images. It is adjustable from 0~100. Contrast: to increase or decre

Strany 18

EAN900 25Advanced Setting Lens Setting LENS: Select DC or Fixed of the lens type used for camera. DC: DC driven Lens Fixed: Manual Lens IRIS Le

Strany 19

EAN900 264.5 Audio The EAN900 camera can transmit audio to other clients using a built-in microphone or connecting to external microphone to play

Strany 20

EAN900 274.6 USER User Information Maximum 10 users can be set for using the IP camera. The user information displays the authorized users and a

Strany 21 - 4.4 Video

EAN900 284.7 EVENT An event in the camera is when an Event Type is activated and causes certain actions to be performed. The event type is the set

Strany 22

EAN900 294.7.1 Event The settings relating to event occurrences such as settings for the event occurrence, motion, alarm and time mask can be conf

Strany 23

EAN900 3About this document All the safety and operating instructions should be read and followed before the unit is operated. This manual should

Strany 24

EAN900 30To change the priority of events, click on the event and it will be highlighted. Press or button to move between events. The event th

Strany 25

EAN900 315. Check “Enable Pre-alarm Buffer” and “Enable Post-alarm Buffer”. For pre-and post alarm buffer setting, please refer to “4.7.3 Alarm”.

Strany 26 - 4.5 Audio

EAN900 32 There are 5 motion trigger areas, which can be distinguished by 5 different colors. Check Enable checkbox to enable event action. For ea

Strany 27 - 4.6 USER

EAN900 33Pre-Alarm Buffer: Image saved internally in the server from the time immediately preceding the trigger. Input the desired length of pre-t

Strany 28 - 4.7 EVENT

EAN900 34Select Always for event action to be taken continuously. Press button to add new time period. Mask name: Input a mask name for the new

Strany 29

EAN900 354.8 SYSTEM Date/Time, Daylight Saving, SD card and Maintenance settings can be performed on this page. The "System" page has 4

Strany 30

EAN900 36Set Date/Time Manually Date: Click the calendar and pick the date. Press << to go previous year, < to go previous month, > t

Strany 31

EAN900 374.8.2 Daylight Saving Set Daylight Saving Check Enable Daylight Saving checkbox to enable daylight saving. Set the start time to day

Strany 32

EAN900 38Press Apply to apply the setting changes or Reset to reset without saving the change. 4.8.3 SD Card Setup SD Card Notification: Notif

Strany 33

EAN900 39OFF for not overwriting SD card data. Press Apply to apply the setting changes or Reset to reset without saving the change. SD Card U

Strany 34

EAN900 4 Do not operate the appliance beyond its specified temperature, humidity or power source ratings. Do not use the appliance in an extreme

Strany 35 - 4.8 SYSTEM

EAN900 404.8.4 Maintenance Maintenance Server Reboot: The unit is rebooted without changing any of the settings. Use this method by pressing Reb

Strany 36

EAN900 41the Load button. The settings will be restored to the previous configuration. Upgrade Firmware Upgrade the EAN900 with the latest firmw

Strany 37

EAN900 425. SPECIFICATIONS CAMERA Pickup Device 1/3" Progressive scan CMOS 1.3 Megapixel Pixel Effective 1280 (H) x 1024 (V) Sensitivity 0

Strany 38

EAN900 43Power Over Ethernet Yes (PoE 802.3af) Power Consumption 4.5W max. (12VDC) PHYSICAL Weight 500 g / 1.102 LBS Dimensions 68 (W) x 57

Strany 39

EAN900 44 China Office: Room B-05D-1, KESHI PLAZA, Shangdi Information Industry Base,Haidian District, Beijing China 100085 TEL: +86-10-62973336/

Strany 40

EAN900 5 TABLE OF CONTENTS1. INTRODUCTION...6 2.

Strany 41

EAN900 61. INTRODUCTION The EAN900 network camera with a built-in 1.3 mega-pixel progressive scan CMOS offers crisp images with sharp definition a

Strany 42 - 5. SPECIFICATIONS

EAN900 7 camera video. Please click "Yes". Step 6. Congratulation!! You should be able to see the live image now. 1. Press but

Strany 43

EAN900 85. View Size You can select View size to either reduce or enlarge the image to the appropriate view size. Select the view size for liv

Strany 44 - EverFocus

EAN900 9 11. Manual Control – Trigger Event Press “Trigger Event” button to trigger an event directly from live view page, and event actions wil