Strany 1 - EPTZ3100/EPTZ3100I

Speed Dome EPTZ3100/EPTZ3100I USER MANUAL Date: Jan. 2009

Strany 2 - Table of Contents

10 1.3.2. EPTZ3100/EPTZ3100I Base Board The base board that is inside the top housing connects to power cable, video cable, control cable, alarm c

Strany 3

11 Pin # Function 1 ALM_NO_B (Alarm Output Normal Open B) 2 ALM_COM_B (Alarm Output Common B) 3 ALM_NC_B (Alarm Output No

Strany 4

12 1.4. EPTZ3100/EPTZ3100I Quick Operation Guide (Work with EKB500) EPTZ3100/EPTZ3100I and EKB500 (Keyboard) can work together by using factory defa

Strany 5 - 1.1. Introduction

13 2. EPTZ3100/EPTZ3100I INSTALLATION 2.1. Packing List There are 3 boxes that are camera main body with a camera module, top housing with a base b

Strany 6

14 * EKB500 (Keyboard) * EKB200 (USB Controller Keyboard)

Strany 7 - 1.2. Specifications

15 2.2. Cable Needed Power Cable An adapter with 24VAC/3.5A output provides the power to the EPTZ3100/EPTZ3100I. An extension power line may be nee

Strany 8

16 terminal resistance settings. All of the settings should be confirmed before the dome is installed. The control-related setting that is address,

Strany 9 - 1.3. Feature

17 Note: You will see the label of Protocol & Baud Rate as well as RS-485 ID address show on the speed dome. White part represents the swit

Strany 10

18 ON1 2 3 4 5 6 7 8Switch Address1ON1 2 3 4 5 6 7 82ON1 2 3 4 5 6 7 83ON1 2 3 4 5 6 7 84ON1 2 3 4 5 6 7 85ON1 2 3 4 5 6 7 86ON1 2 3 4 5 6 7 87ON1 2

Strany 11

19 ON1 2 3 4 5 6 7 8Switch Address129ON1 2 3 4 5 6 7 8130ON1 2 3 4 5 6 7 8131ON1 2 3 4 5 6 7 8132ON1 2 3 4 5 6 7 8133ON1 2 3 4 5 6 7 8134ON1 2 3 4 5

Strany 12 - Zoom INZoom OUT

2 Table of Contents 1. EPTZ3100/EPTZ3100I OVERVIEW...5 1.1. Introduction ...

Strany 13 - 2.1. Packing List

20 2.3.2. Communication Protocol Setting The 1st, 2nd and 3rd bits are used to set communication protocol. The factory default protocol is EVF.

Strany 14 - Keyboard)

21 2.4. Bracket and Speed Dome Installation 2.4.1. Installation Requirements 1. Installation should be handled by a qualified service agent and sh

Strany 15 - 2.3. Initial Setup

22 2.4.2. EPTZ3100 Dome Camera Wall Mount Simple Installation 1. Screw the top housing to bracket by using a hexagon wrench. 2. Put the water

Strany 16

23 3. Connect the cable you detached from base board to the RS485 cable, Power cable and video cable you thread from the wall or ceiling. RS485 cabl

Strany 17

24 5. Screw in 4 long screws to fix the bracket to bracket base.

Strany 18

25 Pull here to open 2.4.3. EPTZ3100 Dome Camera Wall Mount Installation Note: Installation location that is a wall, a pole or a ceiling needs t

Strany 19

26 Pull open this switch 2. Apply the adhesive stripe at back of desiccant pack to the inner side of the top housing. There are totally 3 desiccant

Strany 20 - 1200 BPS

27 4. Put the waterproof silicon pad on top of the base board for waterproof purpose. 5. Connect the cable you detached from base board to

Strany 21

28 6. Screw in 4 screws for mounting the bracket base. 7. Thread the cable through the bracket.

Strany 22

29 8. Screw the top housing to bracket by using a hexagon wrench. 9. Screw in 4 long screws to fix the bracket to bracket base.

Strany 23

3 3. EPTZ3100/EPTZ3100I CAMERA SETUP MENU...38 3.1. Structure of the Setup Menu ...

Strany 24

30 10. Pull the hole of base board to open it again. Connect the power and RS485 wires back to power pin and RS485 pin. If you need to connect alarm

Strany 25

31 Note 1: When you push the orange buttons to detach the main body from bracket, please hold the main body carefully, otherwise it may fall down

Strany 26

32 Note 1: In order to protect the bubble from dirt and scrape, please put on the gloves before installing the bubble. Note 2: The camera module on

Strany 27

33 2. Screw the 3 screws of EPTZ top housing to the 3 holes of indoor recessed mount bracket. 3. Put the indoor recessed mount bracket to the h

Strany 28

34 5. Snap main body to the indoor recessed mount bracket. NOTE: Aim the Arrow label of the main body to the same Arrow label of the bra

Strany 29

35 7. Aim bracket’s fillister to surface ring’s fillister, turn it until it is firmly fixed.

Strany 30

36 2.5. Bracket and Adapter 2.5.1. Indoor Ceiling Pendent Mount Bracket The indoor ceiling pendent mount bracket is used for installi

Strany 31

37 2.5.3. Corner Mount Adapter The corner mount is used for installing a wall mount bracket to a 270° corner of walls indoors or outdoors. 2.5.4

Strany 32

38 3. EPTZ3100/EPTZ3100I CAMERA SETUP MENU In this section, setup and operation guide of EPTZ3100/EPTZ3100I will be introduced. There are 9 items o

Strany 33

39 3.2. VIDEO SETTINGS In main menu, turn joystick Up / Down to select VIDEO SETTINGS. Turn joystick Left / Right to enter VIDEO SETTINGS sub-menu (

Strany 34

4 3.5.8. EXIT ...60 3.6. ALARM ...

Strany 35

40 EL.SHUTTER: Select electronic shutter mode from the options of the menu. There are AUTO, A.FLK , 1/50, 1/160 , 1/250 , 1/1000 , 1/2500, 1/1000

Strany 36 - 2.5. Bracket and Adapter

41 sec for PAL. AUTO X8, AUTO X12, AUTO X16, AUTO X32, AUTO X64, and AUTO X128 work the same as AUTO X4 with different times of shutter speeds. NOT

Strany 37

42 MANUAL: Enable the manual focus mode. 3.2.3. DIGITAL ZOOM Magnification of the digital zoom can be selected among OFF, 2X, 4X and 8X. OFF: Disa

Strany 38 - (diagram 3.1)

43 increased sensitivity in low light environments. Select from AUTO, DAY and NIGHT NIGHT: IR cut filter is always removed (ICR ON). DAY: IR cut f

Strany 39 - 3.2. VIDEO SETTINGS

44 Notice: When the wide dynamic range is ON, some part of the image may appear solarized. This is normal for the wide dynamic range, and is not

Strany 40

45 3.3. POSITIONS In main menu, turn joystick Up or Down to select POSITION option. Press Enter key or turn joystick Left / Right to enter POSITION

Strany 41

46 (diagram 3.6) POSITION: Select from SET and CLEAR. SET: Select SET and press Enter key of keyboard, you will be entered to a sub-menu. Turn th

Strany 42

47 SPEED: Select the speed for the preset position. The value is from 1 to 255 and 255 is the highest speed. DWELL TIME (S): Select the dwell ti

Strany 43

48 3.4. OSD/AREAS In main menu, turn joystick Up or Down to select OSD/AREAS. Turn joystick Left or Right to enter OSD/AREAS sub-menu (see diagram 3

Strany 44

49 In zone menu, you can set a zone and name it, when the speed dome turns to the zone you set, it will display zone name on the screen (only if “OS

Strany 45 - 3.3. POSITIONS

5 1. EPTZ3100/EPTZ3100I OVERVIEW 1.1. Introduction EPTZ3100 series has 2 types, EPTZ3100 is outdoor type whereas EPTZ3100I is indoor type, using

Strany 46 - (diagram 3.7)

50 Turn joystick Right/Left to highlight the zone you have set and turn the joystick Up/Down to select another zone number. If you wish to clear the

Strany 47

51 3. Press IRIS+ key of keyboard to save and return. (diagram 3.14) 4. Go to “DEFAULT NORTH” and press Enter key to set the north positio

Strany 48 - 3.4. OSD/AREAS

52 3.4.4. DISPLAY Press Enter key of keyboard or turn joystick Left/Right to enter DISPLAY sub-menu (see diagram 3.15) (diagram 3.15) 1. SHOW O

Strany 49 - (diagram 3.11)

53 4. ZONES YES: show zones NO: do not show zones 5. PRESET TITLE YES: show preset title NO: do not show preset title 6. ZOOM YES: show zoom multi

Strany 50 - (diagram 3.13)

54 3.4.5. EXIT Select Exit to save settings and exit from current page. 3.5. AUTO MODES In main menu, turn joystick Up/Down to select AUTO MODES.

Strany 51 - (diagram 3.14)

55 a. ENDLESS MODE ON: enable endless mode. The speed dome will perform 360 degree endless auto-pan. OFF: disable endless mode. The speed dome

Strany 52 - (diagram 3.15)

56 (diagram 3.18) f. SET RIGHT POS. Press Enter key or turn the joystick Left/Right to enter SET RIGHT POS. menu. Turn the joystick to the positio

Strany 53

57 g. DEFAULT ON: all settings in AUTOPAN menu will be returned to default values. OFF: the setting in AUTOPAN menu is not default value. h. RE

Strany 54 - 3.5. AUTO MODES

58 setting of preset position. e. PREV PAGE/NEXT PAGE: Turn the joystick Left to go previous page or turn joystick Right to go next page. f. RET

Strany 55

59 d. Turn the joystick to record the tour you wish to set. Press IRIS+ when you finish setting pattern tour. Press IRIS- if you wish to cancel thi

Strany 56 - (diagram 3.19)

6  192 preset positions are available.  16 cruise tours can be set, and each tour contains up to 16 positions.  Up to 256 speed domes can be s

Strany 57 - (diagram 3.20)

60 MODE, POS.1 (H), TOUR1, PAT.1 and AUTOPAN. 3.5.6. POWER UP FUNC Turn the joystick Left or Right to select the mode to return to when power fail

Strany 58 - (diagram 3.22)

61 a. Go to INPUT NO. selection and turn the joystick Left/Right to select alarm input number from 1 ~4. b. Type: Select Normal Close (NC), Norm

Strany 59 - (diagram 3.23)

62 PATTERN: When the alarm is triggered, speed dome will run the pattern. Turn the joystick Left/Right to select on Pattern and press Enter key

Strany 60 - 3.6. ALARM

63 3.6.2. ALARM OUTPUTS Press Enter key of keyboard to enter ALARM OUTPUTS sub-menu. (see diagram 3.26) (diagram 3.26) a. OUTPUT NUM: Select Out

Strany 61 - (diagram 3.25)

64 Select NO to disable this function. i. RETURN: RETURN to the previous menu. 3.6.3. MOTION DETECT Press Enter key of keyboard to enter MOTION

Strany 62

65 3.7. PRIVATE ZONES In main menu, turn joystick Up/Down to select PRIVATE ZONES masking. Turn joystick Left/Right to enter PRIVATE ZONE sub-menu (

Strany 63 - (diagram 3.26)

66 c. Select the area to be covered first. Turn joystick Left/Right to adjust width of the private zone area. Turn joystick Up or Down to adjust h

Strany 64 - (diagram 3.28)

67 3.8. SYSTEM In main menu, turn joystick Up/Down to select SYSTEM. Turn joystick Left/Right to enter SYSTEM sub-menu (see diagram 3.32) (diagram 3

Strany 65 - 3.7. PRIVATE ZONES

68 PASSWORD ACTIVE: Select YES to activate password mode. Select NO to disable password mode. ENTER PASSWORD: Enter the password VERIFY PASSWORD:

Strany 66 - (diagram 3.31)

69 c. BAUDRATE: shows baud rate of this speed dome d. RS-485-ID: shows RS-485 ID of this speed dome e. PRESET-CNT: Preset counter. This counter c

Strany 67 - 3.8. SYSTEM

7 1.2. Specifications Product Model EPTZ3100 (outdoor) EPTZ3100I (indoor) Pickup Device 1/4” CCD Video Format NTSC or PAL Scanning System NTS

Strany 68 - 3.9. INFO

70 4. EPTZ3100/3100I FUNCTION SETUP AND OPERATION 4.1. Manual Control Mode  Manual control: Shift Joystick Up/Down/Left/Right, and turn it Clockw

Strany 69 - 3.10. EXIT

71 4.3. Position Setting  Focus on a preset position: Press the number key, and then press Position to focus on the number of preset position; or

Strany 70 - 4.2. Auto Pan Mode

72 speed. Dwell time: default is 2 sec; It can be changed by EVF Keyboard Set + A.Pan setting dwell time of A pos or B pos. 99 => Auto scan (360

Strany 71 - 4.3. Position Setting

73  One-way tour Mode: Press Tour to enter the tour mode. The system will ask you to enter the tour number you would like to run, and starts the t

Strany 72 - 4.4. Tour Mode

74 If you set the position number to 99, the dome will do a 360 degree auto scan or AB two point pan if limit is ON. If you set the position number

Strany 73

75 EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886-2-26982334 FAX: +886-2-26982380

Strany 74 - 4.6. Other Operations

8 Horizontal Rotation Speed 0.01°/s -360°/s (1-255 grade shift gears) Horizontal Rotation Range 360° unlimited rotation Tilt Rotation Range 180° pe

Strany 75 - EverFocus Electronics Corp

9 1.3. Feature 1.3.1. Profile of EPTZ3100/EPTZ3100I Wall Mount Bracket Sun shield (optional) Bubble Camera main body Top housing Camera module O